7-72
Pn301.3 Position Pulse Command Filter Width Selection
【
5-4-1
】
Initial Value Unit Setting Range Effective Cn029 Reset
1 -- 0 ~ 7
★
--
RS-485 CANopen EtherCAT Pi Pe Pt S T
0301H - - -- O -- -- --
Setting Description:
Setting Description Setting Description
0 4500KHz 4 370KHz
1 2500KHz 5 190KHz
2 1200KHz 6 90KHz
3 750KHz 7 40KHz
Pn302 Electronic Gear Ratio Numerator 1
【
5-4-3
】
Initial Value Unit Setting Range Effective Cn029 Reset
1 -- 1 ~536870912 -- --
RS-485 CANopen EtherCAT Pi Pe Pt S T
0302H/0303H - - O O -- -- --
Setting Description: Please check if Pn354 = 0~63 is set when using functions of Pn302~Pn306. DigitalInput Contact
GN1, GN2 can be used to switch four sets of Electronic Gear Ratio Numerators. When using
Electronic Gear Ratio Numerator 1, the DigitalInput Contact GN1, GN2 states are as the following
combination:
Digital input contact
GN2
Digital input contact
GN1
0 0
Pn303 Electronic Gear Ratio Numerator 2
【
5-4-3
】
Initial Value Unit Setting Range Effective Cn029 Reset
1 -- 1 ~ 536870912 -- --
RS-485 CANopen EtherCAT Pi Pe Pt S T
0304H/0305H - - O O -- -- --
Setting Description: Please check if Pn354 = 0~63 is set when using functions of Pn302~Pn306. DigitalInput Contact
GN1, GN2 can be used to switch four sets of Electronic Gear Ratio Numerators. When using
Electronic Gear Ratio Numerator 1, the DigitalInput Contact GN1, GN2 states are as the following
combination:
Digital input contact
GN2
Digital input contact
GN1
0 1