Pn304 Electronic Gear Ratio Numerator 3
5-4-3
Initial Value Unit Setting Range Effective Cn029 Reset
1 -- 1 ~ 536870912 -- --
RS-485 CANopen EtherCAT Pi Pe Pt S T
0306H/0307H - - O O -- -- --
Setting Description: Please check if Pn354 = 0~63 is set when using functions of Pn302~Pn306. DigitalInput Contact
GN1, GN2 can be used to switch four sets of Electronic Gear Ratio Numerators. When using
Electronic Gear Ratio Numerator 1, the DigitalInput Contact GN1, GN2 states are as the following
combination:
Digital input contact GN2 Digital input contact GN1
1 0
Pn305 Electronic Gear Ratio Numerator 4
5-4-3
Initial Value Unit Setting Range Effective Cn029 Reset
1 -- 1 ~ 536870912 -- --
RS-485 CANopen EtherCAT Pi Pe Pt S T
0308H/0309H - - O O -- -- --
Setting Description: Please check if Pn354 = 0~63 is set when using functions of Pn302~Pn306. DigitalInput Contact
GN1, GN2 can be used to switch four sets of Electronic Gear Ratio Numerators. When using
Electronic Gear Ratio Numerator 1, the DigitalInput Contact GN1, GN2 states are as the following
combination:
Digital input contact GN2 Digital input contact GN1
1
1
Pn306
Electronic gear ratio denominator /CNC cutter head denominator minus
ratio
5-4-3
Initial Value Unit Setting Range Effective Cn029 Reset
1 -- 1 ~ 536870912
--
RS-485 CANopen EtherCAT Pi Pe Pt S T
030AH/030BH - - O O -- -- --
Setting Description: Please check if Pn354 = 0~63 is set when using functions of Pn302~Pn306. Set Pn306 (Electronic
Gear Ratio Denominator) and match the Electronic Gear Ratio Numerator selected by Digital Input
Contact GN1, GN2. The obtained Electronic Gear Ratio must conform to the following conditions,
otherwise this Device cannot operate normally.