7-114
tn833 Program Jog stroke stop time4-4
Initial value Unit Setting range Effective Cn029 reset
2500 0.4ms 5 ~ 25000 -- --
Setting description: Program Jog stroke stop time
tn834 Program Jog stroke acceleration/deceleration time4-4
Initial value Unit Setting range Effective Cn029 reset
250 0.4ms 5 ~ 25000 -- --
Setting description: Program Jog stroke acceleration/deceleration time
tn835 Program Jog stroke movement maximum speed4-4
Initial value Unit Setting range Effective Cn029 reset
100 rpm 0 ~ 1.5 x rated rotation speed -- --
Setting description: Program Jog stroke movement maximum speed
tn836 Program Jog stroke moving distance4-4
Initial value Unit Setting range Effective Cn029 reset
30 0.1rev 1 ~ 2000 -- --
Setting description: Program Jog stroke moving distance
RS-485 CANopen EtherCAT Pi Pe Pt S T
1321H 2D21H 2D21H O O O -- --
RS-485 CANopen EtherCAT Pi Pe Pt S T
1322H 2D22H 2D22H O O O -- --
RS-485 CANopen EtherCAT Pi Pe Pt S T
1323H 2D23H 2D23H O O O -- --
RS-485 CANopen EtherCAT Pi Pe Pt S T
1324H 2D24H 2D24H O O O -- --