7-115
tn837.0 On-line tuning flag
Initial value Unit Setting range Effective Cn029 reset
0 -- 0 ~ 1 -- --
RS-485 CANopen EtherCAT Pi Pe Pt S T
1325H 2D25H 2D25H O O O
O
--
Setting description:
Setting Description
0 Disable the on-line tuning function
1
Enable stroke operation to enable on-line tuning
function
tn837.1 On-line tuning load convergence selection
Initial value Unit Setting range Effective Cn029 reset
1 -- 0 ~ 2 -- --
RS-485 CANopen EtherCAT Pi Pe Pt S T
1325H 2D25H 2D25H O O O O --
Setting description:
Setting Description
0 Slow load convergence
1 Medium load convergence
2 Fast load convergence
tn837.2 On-line tuning system rigidity selection
Initial value Unit Setting range Effective Cn029 reset
4 -- 0 ~ 7 -- --
RS-485 CANopen EtherCAT Pi Pe Pt S T
1325H 2D25H 2D25H O O O O --
Setting description:
Setting Description
0 Rigidity 0 (small rigidity)
1 Rigidity 1
2 Rigidity 2
3 Rigidity 3
4 Rigidity 4
5 Rigidity 5
6 Rigidity 6
7 Rigidity 7 (great rigidity)