Index Subindex Name
Data
Type
Access
PDO
Mapping
Saving to
EEPROM
Default Value
Supported mode
Unit
Paramet
er No.
Lower
Limit
Upper Limit
All PP PV PT HM IP CSP CSV CST
202Bh 0 MON1 output proportion UINT RW No Yes 100
% Cn043 -1000 1000
202Ch 0 MON2 output proportion UINT RW No Yes 100
% Cn044 -1000 1000
2030h 0
Delay time switching of
2-stage gain mode
UINT RW No Yes 0
x0.2
msec
Cn048 0 10000
2031h 0
Switching conditions of
2-stage gain mode
UINT RW No Yes 0
x0.2
msec
Cn049 0 10000
2032h 0
Switching conditions of
2-stage gain mode
UINT RW No Yes 0
x0.2
msec
Cn050 0 10000
2033h 0
Low voltage protection
level
UINT RW No Yes 190
V Cn051 170 190
2034h 0
Low voltage protection
alarm delay time
UINT RW No Yes 4
x250
msec
Cn052 0 100
2035h 0
Automatic correction of
Current offset(only use in
servo off status)
UINT RW No Yes 0
- Cn053 0 1
2036h 0
Drive warning setting
(AL1-16)
UINT RW No Yes 0
- Cn054 0 0xFFFF
2037h 0
Alarm trigger delay of
drive warning
UINT RW No Yes 0
x10
msec
Cn055 0 300
2038h 0
2nd CCW torque
command limit
INT RW No Yes
300/280/260/250/
240/220/200
% Cn056 0 300
2039h 0
2nd CW torque command
limit
INT RW No Yes
-300
/
-280/-260/-
250/-240/-220/-
200
% Cn057 -300 0
203Ah 0
Delay time of switching
from 1st torque limit to
2nd torque limit
UINT RW No Yes 0
x4
msec
Cn058 0 32767
203Bh 0
Selection of enabling
Auto Tuning
UINT RW No Yes 0
- Cn059 0 2
203Ch 0
The turns command of
OFFLine-tuning
UINT RW No Yes 3
0.1re
v
Cn060 3 1024
203Dh 0
The Maximum speed
OFFLine-tuning
UINT RW No Yes 2/3*rated rpm
rpm Cn061 300 2/3*rated rpm
203Fh 0
Selection of enabling
auto mechanical
suppression
UINT RW No Yes 0
- Cn063 0 5
2040h 0
Mechanical vibration
detection Level
UINT RW No Yes 50
- Cn064 1 1000
2041h 0
Resonance suppression
filter depth
UINT RW No Yes 0
- Cn065 0 1000
2042h 0
2nd point of resonance
suppression filter
frequency
UINT RW No Yes 0
Hz Cn066 0 2000
2043h 0
2nd point of resonance
suppression filter quality
factor
UINT RW No Yes 7
- Cn067 1 100
2044h 0
2nd pointof resonance
suppression filter depth
UINT RW No Yes 0
- Cn068 0 1000
2045h 0
3rd point of resonance
suppression filter
frequency
UINT RW No Yes 0
Hz Cn069 0 2000

Table of Contents