EasyManua.ls Logo

TECO JSDG2S-100A3-E - Page 657

TECO JSDG2S-100A3-E
718 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
8-152
Index Subindex Name
Data
Type
Access
PDO
Mapping
Saving to
EEPROM
Default Value
Supported mode
Unit
Paramet
er No.
Lower
Limit
Upper Limit
All PP PV PT HM IP CSP CSV CST
2046h 0
3rd point of resonance
suppression filter quality
factor
UINT RW No Yes 7
- Cn070 1 100
2047h 0
3rd pointof resonance
suppression filter depth
UINT RW No Yes 0
- Cn071 0 1000
2048h 0
4rd point of resonance
suppression filter
frequency
UINT RW No Yes 0
Hz Cn072 0 2000
2049h 0
4rd point of resonance
suppression filter quality
factor
UINT RW No Yes 7
- Cn073 1 100
204Ah 0
4rd pointof resonance
suppression filter depth
UINT RW No Yes 0
- Cn074 0 1000
204Bh 0
5rd point of resonance
suppression filter
frequency
UINT RW No Yes 0
Hz Cn075 0 2000
204Ch 0
5rd point of resonance
suppression filter quality
factor
UINT RW No Yes 7
- Cn076 1 100
204Dh 0
5rd pointof resonance
suppression filter depth
UINT RW No Yes 0
- Cn077 0 1000
204Eh
0
CANopen
communication write
selection
UINT RW No Yes 0x0100
- Cn078 0x0000 0x0501
204Fh
0
CANopen
communication
transmission rate and
station number setting
UINT RW No Yes 1
- Cn079 1 127
205Fh
0
CANopen detecting bus
off and disconnection
level
UINT RW No Yes 130
- Cn095 128 256
2060h
0
CANopen clear wire
breaking comparsion
level
UINT RW No Yes 100
msec Cn096 0 127
2061h
0
Motor break protrction
flag
UINT RW No Yes 0
- Cn097 0 1
2062h
0
Motor line break
detection time
UINT RW No Yes 3000
msec Cn098 1000 10000
2101h 0
Acceleration/deceleration
operation of torque
command
UINT RW No Yes 0
- Tn101 0 2
2102h 0
Linear
acceleration/deceleration
constant of torque
command
UINT RW No Yes 1
msec Tn102 1 50000
2105h 0
UINT RW No Yes 100
rpm Tn105 0 1.5*rated rpm
2108h 0 Torque reached value UINT RW No Yes 0
% Tn108 0 300
210Ah 0
A
cceleration/deceleration
time constant of single
smoothing (torque
command)
UINT RW No Yes 1
msec Tn110 1 10000
2201h 0
Internal Speed Command
1
INT RW No Yes 100
rpm Sn201
-
1.5*rat
ed rpm
1.5*rated rpm
2204h 0
Motion established by
zero speed judgement
UINT RW No Yes 0
- Sn204 0 1

Table of Contents