5-4
 
5-2 Torque Mode 
The Torque Mode is used for printing machines, winding machines and injection molding 
machines that need to perform Torque Control. The user shall set Cn001 (Control Mode Selection) in 
accordance with the mode to be used. The setting method is as follows: 
 
Cn001 Control Mode Selection 
Initial Value  Unit  Setting Range  Effective  RS-485 Address 
2  --  0 ~ E  Power Re-set  0001H 
Setting Description:   
Setting  Description 
0 Torque Control 
4  Speed / Torque Control Switching 
5  External Position / Torque Control Switching 
8  Internal Position / Torque Control Switching 
 
Torque Circuit Control Block is as shown in the Figure below: 
Analog  Torque 
Command TIC
Current 
Feedback
Internal 
Torque 
Limit 
Cn010 
Cn011
Current 
Controller 
Digital input  
Contact 
RS1、RS2
Torque O utput 
Direction 
Cn004.0
Digital input  
Contact 
TRQINV
Once 
Smoothing 
Acceleration / 
Deceleration 
Tn110
Acceleration / 
Deceleration 
Method 
Tn101.0
Digital Input 
Contact SPD1, 
SPD2
Speed Limit 
Condition
Digital Torque Command Tn113
Speed Limit 
Switching 
Tn101.2
To rq ue Command Se lecti on 
Tn101.1
Speed Control 
Circuit
0
0
1
1
2
True
Internal Speed Limit 
Tn105~Tn107
Internal Positive 
Negative 
Speed Limit 
Tn114, Tn115
External Speed 
Limit SIC
Torque 
Command 
Proportioner 
Tn103
A/D
A/D
Speed Limit 
Voltage 
Offset 
Sn217
Actual Motor 
Torque 
Un-02
External Analog 
Voltage Limit 
Un-11
Torque 
Command 
Un-28
Torque 
Command 
Smoothing 
Filter 
Cn034
Speed Limit 
Proportioner 
Tn109
External Analog 
Voltage Command 
Un-09
False
Torque 
Direction
Straight Line 
Acceleration / 
Deceleration 
Tn102
Not Used
Torque 
Command 
Voltage 
Offset 
Tn104
Analog 
Speed 
Command 
Filter 
Sn226
 Linear 
Acceleration / 
Deceleration 
Separation  
Tn110 / Tn117 
3
 
 
Parameters  Description  Setting range  Unit 
Take effect 
method 
Related 
chapter 
CN001  Control mode selection  0.: Torque control  --  Power reset  5-2 
CN004.0 
Rotation direction selection (looking 
from the load of the motor) 
0 ~ 1  --  Power reset  5-2-4 
CN010 
First stage CCW direction torque 
command limit value 
0 ~ 300  % 
Take effect 
after setting 
5-2-5