EasyManua.ls Logo

TECO JSDG2S-20A-EL - 6-15 On-line tuning

TECO JSDG2S-20A-EL
718 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6-49
6-15 On-line tuning
On-line tuning instructions
On-line tuning is the function to obtain stability through auto-tuning regardless of the machine type or
load change status.When the On-line tuning function is enabled, the system will adjust automatically.
 
Notes
The On-line tuning function is invalid under torque control mode.
The On-line tuning function cannot be enabled when automatic gain tuning (Off-line tuning)
is executing.
The maximum load inertia ratio that can be borne is 30 times. When the motors tolerable
load inertia ratio is exceeded, vibrations will be generated; at this time, reduce the system
rigidity selection (tn837.2 = H'X□□).
To ensure the safety while On-line tuning is operating, please execute it under the condition
where an emergency stop can be used at any time.
Functions that will become invalid when On-line tuning is effective
P/PI control switch function (Cn015.0 = H'□□□X)
Two-stage gain switch function (Cn015.1 = H'□□X)
Friction compensation control (tn841.0 = H'□□□X)
Speed observer (tn838.0 = H'□□□X)
Parameters that will be adjusted automatically when On-line tuning is
effective
Load inertia ratio Cn025
Torque command filter Cn034
Speed circuit gain Sn211
Speed circuit integral time constant Sn212
Position circuit gain Pn310

Table of Contents