5-80
Speed
Position
Pn318 (First stage high speed)
Pn317.2=2
Pn317.0=6
Digital input contact
SHOME
Pn319 (Stage two low speed)
Pn317.3=0
Motor en co der Z p hase
pulse
ON
After topped to the stop point
of the mechanism and the
load increased to the Pn361
value and continued for
Pn362 time, set to the position
reference point
(11) Pn317.0=8, Pn317.1=2
(After the origin reset has started, the motor uses the first stage speed forward direction to search
for the origin, and completes the origin reference position according to the setting conditions of
Pn361 and Pn362)
Pn361 (Origin reset torque limit value)
Pn362 (Torque stabilization continuous time)
Speed
Position
Pn318 (First stage high speed)
Pn317.2=2
Digital input contact
SHOME
ON
After topped to the stop point of the
mechanism and the load increased
to the Pn361 value and continued
for Pn362 time, set to the position
reference point