5-106
5-5-3-1 Compound tool magazine dedicated mode – tool magazine
calibration reset to zero mode timing diagram
Update tool handle reset to
zero position
Signal trigger
DI-MDC2
Signal trigger delay
(Pn334)
Tool disc reset to
zero postion
(Pn325)
Tool number
output signal
DO-P1~6
Positioning
complete signal
DO-INP
Pn334
50ms
Mode switch 1/3/4
DI-MDC1/3/4
Old tool handle reset to zero
position

Table of Contents