5-146
Cn044 Analog monitoring output MON2 output proportion JSDG2S-E(L) does not
have this function
Initial Value Unit Setting Range Effective RS-485 Address
100 % -1000 ~ 1000 Effective after Confirmed 002FH
Setting Description: Please refer to the setting description of Cn043.
Following diagram shows the wiring of analog monitoring output:
When offset of analog monitoring output voltage occurs, the user can manually adjust Cn027, Cn028
to correct the offset. Refer to the following setting:
Cn027 Analog monitoring output 1 offset adjustment JSDG2S-E(L) does not have
this function
Initial Value Unit Setting Range Effective RS-485 Address
0 40mV -250 ~ 250 Effective after Confirmed 001EH
Cn028 Analog monitoring output 2 offset adjustment JSDG2S-E(L) does not have
this function
Initial Value Unit Setting Range Effective RS-485 Address
0 40mV -250 ~ 250 Effective after Confirmed 001FH
Setting Description: Used to correct the offset when it occurs on analog monitoring output 1/2
voltage.