EasyManua.ls Logo

TECO JSDG2S-20A-EL - Page 652

TECO JSDG2S-20A-EL
718 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
8-147
Index Subindex Name
Data
Type
Access
PDO
Mapping
Saving
to
EEPROM
Default Value
Supported mode
Unit
Param
eter
No.
Lower
Limit
Upper Limit
All
PP PV PT HM IP CSP CSV CST
2
Driving shaft
revolutions
UDINT RW No YES 1
- En711 1 536870911
6093h*
Position factor
0 Number of entries USINT RO No No 2
- - - -
1 Numerator UDINT RW No YES 1
- En701 1 536870911
2 Feed_constant UDINT RW No YES 1
- En702 1 536870911
6095h*
Velocity factor
0 Number of entries USINT RO No No 2
- - - -
1 Numerator UDINT RW No YES 1
- En703 1 536870911
2 Divisor UDINT RW No YES 1
- En704 1 536870911
6097h*
Acceleration factor
0 Number of entries USINT RO No No 2
- - - -
1 Numerator UDINT RW No YES 1
- En705 1 536870911
2 Divisor UDINT RW No YES 1
- En706 1 536870911
6098h 0 Homing Method SINT RW YES No 1
- - 0 37
6099h
Homing Speed
0 Number of entries USINT RO No No 2
- - - -
1
Speed during search
for switch
UDINT RW YES No 50000
Vel.
Unit
- 0 4294967295
2
Speed during search
for zero
UDINT RW YES No 50000
Vel.
Unit
- 0 4294967295
609Ah 0 Homing acceleration UDINT RW YES No 0
Acc.
Unit
- 0 4294967295
60B0h 0 Position Offset DINT RW YES No 0
- -
-
21474
83648
2147483647
60B1h 0 Velocity Offset DINT RW YES No 0
Vel.
Unit
-
-
21474
83648
2147483647
60B2h 0 Torque Offset INT RW YES No 0
0.10
%
-
32768
32767
60B8h 0 Touch probe function UINT RW YES No 0
- - 0 0xFFFF
60B9h 0 Touch probe state UINT RO YES No 0
- - - -

Table of Contents

Related product manuals