603F
h
Error code
3001
h
Error Code
Alarm Clearing
Method
AL.027 Synchronous error is too large 0x8611-01-0027 Switch Reset
AL.028 Self-build Motor Parameter Error 0x5220-01-0028 Power Re-set
AL.029
CANopen/EtherCAT
communication Disconnected
0xff00-80-0029 Switch Reset
AL.030
Modbus Communication Timeout
Error
0x7510-01-0030 Switch Reset
AL.032
Linear Motor Magnetic Pole
Alignment Error
0xff03-80-0032 Switch Reset
AL.033 Driver Chip Error 0x5220-01-0033 Power Re-set
AL.034 Excessive Dividing Frequency 0x5444-01-0034 Switch Reset
AL.035 Auto tuning Error 0x6100-01-0035 Switch Reset
AL.036
Linear Motor Alignment not
Completed
0xff01-01-0036 Switch Reset
AL.037 Regenerative Error 0xff04-20-0037 Switch Reset
AL.038 Start Up Circuit Error 0xff05-20-0038 Power Re-set
AL.039
Full-closed Loop Encoder
Matching Error
0x7305-80-0039 Power Re-set
AL.040
Turret Mode is prohibited to use
non-absolute type encoder
0x7305-80-0040 Power Re-set
AL.041 Control Mode Selection Error 0x6320-80-0041 Power Re-set
AL.042 Dividing Setting Error 0x6320-80-0042 Power Re-set
AL.043
EtherCAT/CANopen
communication mode is abnormal
Son
0xff04-80-0043 Power Re-set
AL.044
Internal Position S Curve Setting
Error
0x6320-80-0044 Switch Reset
AL.045
Communication Type Encoder
Model Error
0x7305-80-0045 Power Re-set
AL.046 Encoder Feedback Value Error 0xff05-80-0046 Power Re-set
AL.047 Turret Origin Return to Zero Error 0xff04-80-0047 Switch Reset
AL.048
EtherCAT/CANopen
Communication Mode Setting
Error
0x6320-80-0048 Switch Reset
AL.049 EtherCAT Synchronous Error 0xff00-80-0049 Switch Reset
AL.050 Absolute Type Encoder Position 0x7305-80-0050 Power Re-set