3-4
Steps
Operation
Key
LED Display Screen
after Operation
Description
17
Press MODE Key once to enter
Status Display
Screen
. Cycle through in sequence.
Can be modified Cn035 to monitor parameters.
§Monitoring display when power is turned on
By setting Cn035 (panel status display content selection), the display content after power-on can be
set to monitor parameter (Un-□□) display instead of the status display screen.
Cn035 Panel status display content selection
Initial
Value
Unit Setting Range Effective RS-485 Address
0 -- 0 ~ Un parameter maximun
Effective
after setting
0026H
Setting description:
Setting Description
This parameter can set the panel status display content after power-on
0
Display bit data and status code, please refer to [3-1 Driver Panel Operation
Instructions]
1 ~ Maximun
To display the contents of the Un status display parameters, please refer to [7-3-
12 Monitoring Parameters].
Example: When Cn035=1, the actual motor speed (Un-01 content) will be
displayed on the panel after power is turned on.