Command Descriptions
TDS200, TDS1000/2000, TDS1000B/2000B, TPS2000 Programmer
2-87
DATa:DESTination?
REF<x> is the reference memory location where the waveform will
be stored.
DATa:DESTINATION REFA
Stores incoming waveform data into reference memory REFA.
DATa:DESTINATION?
Might return REFB as the waveform location that is currently
selected.
CURVe?
DATa:ENCdg
Sets or queries the format of the wave form da ta. This command is
equivalent to setting WFMPre:ENCdg, WFMPre:BN_Fmt, and
WFMPre:BYT_OrasshowninTable2--29onpage2--88.
Setting the DATa:ENCdg value causes the corresponding WFMPre
values to update. Setting the WFMPre value causes the correspond-
ing DATa:ENCdg values to update.
Waveform
DATa:ENCdg { ASCIi | RIBinary | RPBinary | SRIbinary |
SRPbinary }
DATa:ENCdg?