TMP4100-Series Installation/Maintenance
1-4 33480D01.DOC
1.2.4 Filter/Regulator Unit
TMP4100E: The TMP4100E does not employ a filter/regulator unit. It uses an electric solenoid to drive the
pin and an internal spring to assist pin return.
TMP4100: The filter/regulator unit includes a regulator with a coarse filter and a pressure gauge to control the
drive air. The unit also includes a coalescing filter to remove finer particles. The drive air fires the pin from
the cartridge.
TMP4150, TMP4155: The filter/regulator unit includes two regulators with pressure gauges to control the drive
air and return air. The first regulator contains a filter to help remove contaminants from the supply air. The
drive air fires the pin from the cartridge. The return air pushes the pin back into the cartridge.
Temperature............................32° to 122°F (0° to 50°C)
Operating Pressure..................120 psi (8.3 bars) maximum
1.2.5 Storage and Handling Requirements
Do not drop the containers.
Shock......................................75G/11ms half sine-wave
Vibration.................................1.04G (2-200 Hz) random RMS
Store all containers in a dry, heated, non-condensing environment.
Temperature............................-4° to 113°F (-20° to 45°C)
Humidity.................................5% to 95%
Store all containers away from splashing or sprayed moisture.