Device Installation
The TW-EAV510 connects two separate physical interfaces, an xDSL (WAN) and an Ethernet
(LAN) interface. Place the Router in a location where it can be connected to the various
devices as well as to a power source. The Router should not be located where it will be
exposed to moisture or excessive heat. Make sure the cables and power cord are placed
safely out of the way so they do not create a tripping hazard. As with any electrical appliance,
observe common sense safety procedures.
The Router can be placed on a shelf or desktop, ideally you should be able to see the LED
indicators on the front if you need to view them for troubleshooting.
Power on Router
The Router must be used with the power adapter included with the device.
1. Insert the DC Power Adapter cord into the power receptacle located on the rear panel of the
Router and plug the adapter into a suitable nearby power source.
2. Depress the Power button into the on position. You should see the Power LED indicator light
up and remain lit. The Status LED should light solid green and begin to blink after a few
seconds.
3. If the Ethernet port is connected to a working device, check the LAN LED indicators to make
sure the connection is valid. The Router will attempt to establish the xDSL connection, if the
xDSL line is connected and the Router is properly configured this should light up after several
seconds. If this is the first time installing the device, some settings may need to be changed
before the Router can establish a connection.
Factory Reset Button
The Router may be reset to the original factory default settings by using a ballpoint or paperclip
to gently push down the reset button in the following sequence:
1. Press and hold the reset button while the device is powered off.
2. Turn on the power.
3. Wait for 10 seconds and then release the reset button.
Remember that this will wipe out any settings stored in flash memory including user account
information and LAN IP settings. The device settings will be restored to the factory default IP
address 192.168.0.254 and the subnet mask is 255.255.255.0, the default management
Username is “admin” and the default Password is “admin.”