EasyManua.ls Logo

Tennant T5 - On-Board Battery Charger Settings

Tennant T5
42 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
OPERATION
Tennant T5 (12- 13)
21
ON- BOARD BATTERY CHARGER SETTINGS:
If your machine is equipped with the on- board charger ,
the charger settings must be set for your battery type.
Failure to properly set will result in battery damage.
The factory setting is set for the Exide Gel battery.
To determine your battery type, see battery label.
Contact your battery supplier if not specified.
To verify the setting of the charger, connect the charger
cord into an electrical receptacle. The charger will
display a sequence of codes at start up as follows:
SPE, U3.5, 24V, 20A, 02c, GEL. The fifth and sixth
codes are the battery type “02c” and “GEL” .
NOTE: The second code “U3.5” is charger version 3.5.
If the display codes do not match your battery type as
shown in the tables, change the settings accordingly.
Charger Version 3.5
Display Code Battery Type
02c GEL Exide Gel
01c Acd Lead Acid (Wet)
03c GEL Gel (Generic)
Charger Version 3.4 or Earlier
Display Code Battery Type
00c GEL Gel (Sealed)
01c Acd Lead Acid (Wet)
To change the setting, unplug the charger, peel up the
corner of the display label to access the switches
(Figure 46).
FIG. 46
Set the charger switches to your battery type (Fig. 47).
The charger cord must be unplugged when resetting.
LEAD ACID BATTERY
Exide GEL BATTERY
Generic GEL BA TTERY
LEAD ACID BATTERY
GEL BATTERY
Charger Version 3.5
Charger Version 3.4 or earlier
FIG. 47