OPERATION
26
Tennant T5 (06- 06)
To Adjust a Tapered Brush Pattern:
Tools required: 10mm wrench and 6mm hex wrench
1. Raise the scrub head off floor and remove key.
2. Remove the idler plate from the brush (Figure 59).
FIG. 59
3. Hold the brush plug shaft with a wrench and loosen
the 6mm hex screw (Figure 60).
FIG. 60
4. To lower the brush end, turn the shaft clockwise for
the front brush and counter- clockwise for the rear
brush. Retighten hex screw (Figure 61).
FIG. 61
5. Recheck brush pattern.
NOTE: Replace brushes when worn to 15mm.