Model TA50RT
Rev. 1 04/99
SAFETY
2
2 - 7
2.2. SAFETY FEATURES
2.2.1. EMERGENCY STOP PUSHBUTTONS
Two EMERGENCY STOP pushbuttons, one at the ground station and one in the cage, act as power on/off
switches.
Both switches must be ON to operate the machine. When either of the buttons is depressed, all
functions stop immediately and the parking brake is automatically applied and the engine is stopped.
2.2.2. FOOTSWITCH CONTROL
The footswitch must be fully depressed before any machine operation can be carried out from the cage.
When the footswitch control is released, the engine speed is cut back to idle and all machine functions are
terminated.
2.2.3. TILT ALARM
The tilt alarm gives an audible warning when the machine is out of level by more than which the sensor has been
rated and cuts booms functions (allowing boom down only).
2.2.4. MOVEMENT ALARM
The movement alarm is activated as soon as the machine is in drive mode.