Model TA50RT
Rev. 1 04/99
5
5 - 15
MAINTENANCE SCHEDULES
5.3.5.3. Hydraulic Tank Refill Procedure
Refilling the hydraulic oil tank requires approximately 62 litres of TEXACO RANDO HDZ 32 hydraulic oil (or
equivalent).
To refill the hydraulic tank, proceed as follows:-
(a) Ensure that the oil temperature is sufficiently high to allow the oil to flow freely.
(b) Place a suitable container under the drain tap or attached to a suitable hose to lead from the drain tap
to the waste oil container.
(c) Open the drain plug and drain off all the oil from the tank.
(d) Remove the tank top plate to allow the internal inspection and cleaning of the tank.
(e) Renew the suction filter and close the drain plug.
(f) Renew the cover plate, renew the gasket if necessary and refill the reservoir to the correct level,
filling through the return filter.
5.3.5.4. Structural Examination
A thorough examination of the complete machine should be carried out for any signs of damage, corrosion,
misalignment, material fractures, etc. Particular attention must be given to the condition of all welded joints.
5.3.5.5. Cage Mounting
Check the cage mounting as follows:-
(a) Check that all mounting bolts are secure.
(b) Check cage frame members are in good condition.
5.3.5.6. Levelling Cylinders
Check the seals at rod and replace if required.