OPERATING PROCEDURES
3
Model TA50RT
Rev. 1 04/99
3 - 2
3.2. GROUND CONTROL CHECKS
DO NOT OPERATE THE MACHINE IF THE GROUND CONTROL CHECKS REVEAL A
FAULT.
Ensure that the following checks are carried out with the cage empty:
(a) Test all operations (lift, rotate, etc.).
(b) Check for the following:
(i) Uneven or jerky operation
(ii) Hydraulic oil leak.
3.3. CAGE CONTROL CHECKS
DO NOT OPERATE THE MACHINE IF THE CAGE CONTROL CHECKS REVEAL A FAULT.
Ensure that the following checks are carried out on a level surface:
(a) Carry out the checks described in section 3.2.
(b) Check the drive, and emergency braking.
(c) Check the slow drive speed with the lower boom slightly elevated.
(d) Check the fast drive speed with all the booms fully down.