Table 6-9 IBUC M&C Command Set
Parameter
<value> Valid Values
(See Notes Below)
Comments Command Burst/
CSM
Mode
Config
allowed
if slave?
Default Value
HHT
[Note
4]
RS-
232
Port
RS-
485
Port
ASCII
FSK
Port
ASCII
RS-485
Binary(1)
FSK Port
Binary(1)
Telnet
Port
IBUC Operation Manual 6-21
Terrasat Communications, Inc.
Rev. A
Set
Autocloning
0 = Disable,
1=Enable
When Autocloning is
enabled, the
MASTER BUC will
periodically update
the SLAVE BUC with
configuration data.
NOTE a slave with
BCL=0, will still
become a clone of
master and BCL will
become 1.
Configuration data
includes C4D, C4M,
C4R, C4V, CPS,
CPT, EKO, CM1,
CM2, CMS, BAM
(always cloned),
BSM (always
cloned), BCL
(always cloned),
TAH, TAL, TAZ,
TBH, TBL, TBN,
TBT, TFR, TGC,
TPM, TSD, TSP,
TST, TTS.
BCL=<value> all no 1 X X X X No No X
Get
Redundancy
Switching
Type
0=Manual,
1=Automatic
Gets the redundancy
switching type of the
BUC.
BSM? all na X X X X No No X
Set
Redundancy
Switching
Type
0=Manual,
1=Automatic
Gets the redundancy
switching type of the
BUC. If switching
type is automatic,
then the BUC will
control the switch as
described in BAM. If
Manual, then
redundancy
switching is disabled
- ie only the user can
change the switch.
BSM=<value> all no 1 X X X X No No X
Get Syst
Status
BUCA=Auto or
Manual, OnLine or
Standby or Faulted
BUCB=Auto or
Manual, OnLine or
Standby or Faulted
Returns summary
status of BUCA,
BUCB, and switch.
BST? all na X X X X No No X