Table 6-9 IBUC M&C Command Set
Parameter
<value> Valid Values
(See Notes Below)
Comments Command Burst/
CSM
Mode
Config
allowed
if slave?
Default Value
HHT
[Note
4]
RS-
232
Port
RS-
485
Port
ASCII
FSK
Port
ASCII
RS-485
Binary(1)
FSK Port
Binary(1)
Telnet
Port
IBUC Operation Manual 6-24
Terrasat Communications, Inc.
Rev. A
Set Burst
Threshold
0.0-60.0
(corresponding to
0.0 to 60.0 dBm in
0.1 dB steps).
Further qualified by
ODU output range of
P1dB to P1dB-20dB
Sets the threshold
for burst power
measurement in the
SSPA. All output
power
measurements
above this power
level are considered
to be measurements
taken when burst is
present and are
averaged into burst
power level.
TBT=<value> all no P1dB - 20 X+- X X X X X X
Get Input
Power Sensor
Reading
Returns the current
input power level in
dBm.
TDT? all na X X X X No No X
Get Tx
Frequency
Band
Returns the
frequency band for
the ODU.
TFB? all na X X X X X X X
Get Spectral
Inversion
Reads from LO
Frequency ID table
the spectral
inversion flag based
on which frequency
band the unit is set
for.
TFI? all na X X X X No No X
Get Transmit
Frequency
Returns the RF
frequency. This
value is used
internally to
determine which
elements to use in
the calibration
tables.
TFR? all na X X X X X X X
Set Transmit
Frequency
950-1525 or 5850-
14500. If the former
range, input is
assumed to be at IF.
Conversion to RF
must be performed.
If the latter, no
conversion is
necessary.
Used to determine
what point to use in
the output power
detector calibration
table.
TFR=<value> all no Middle of Tx Band X X X X X X X