Table 6-9 IBUC M&C Command Set
Parameter
<value> Valid Values
(See Notes Below)
Comments Command Burst/
CSM
Mode
Config
allowed
if slave?
Default Value
HHT
[Note
4]
RS-
232
Port
RS-
485
Port
ASCII
FSK
Port
ASCII
RS-485
Binary(1)
FSK Port
Binary(1)
Telnet
Port
IBUC Operation Manual 6-23
Terrasat Communications, Inc.
Rev. A
Set Transmit
Alarm
Simulation
1=On or 0=Off Places alarm relay
into "faulted" state
and sets bit in alarm
Byte. (See CAS?)
TAS=<value> all 0 X X X X No No X
Get Transmit
Alarm
Suppression
Returns current
value Alarm
Suppression
TAZ? all na X X X X No No X
Set Transmit
Alarm
Suppression
1=On or 0=Off Suppresses all Level
Alarms. All other
alarms are still
operational
TAZ=<value> all no 0 X X X X No No X
Get Input
Transmit
Alarm High
Threshold
Returns Input high
power level
threshold
TBH? all na X X X X No No X
Set Input
Transmit
Alarm High
Threshold
-15.0 to -55.0 dBm
(0.1 dB steps).
(Must be above Low
Threshold)
Sets Input high
power Level
threshold. BUC
Controller
continuously reads
the input detector
voltage. Compares
the Input power to
this threshold. A
level alarm is set if
the threshold is
exceeded.
TBH=<value> all no -15 X+- X X X No No X
Get Input
Transmit
Alarm Low
Threshold
Returns Input low
power level
threshold
TBL? all na X X X X No No X
Set Input
Transmit
Alarm Low
Threshold
-15.0 to -55.0 dBm
(0.1 dB steps). Must
be below High
Threshold
Sets Input low power
Level threshold.
(same as TBH
except low
threshold)
TBL=<value> all no -60 X+- X X X No No X
Get Burst
Count
TBN? all na X X X X X X X
Set Burst
Count
1 to 16 Sets the number of
points to average in
the burst power
measurement
TBN=<value> all no 8 X+- X X X X X X
Get Burst
Threshold
Returns the burst
power threshold.
TBT? all na X X X X X X X