ON/MODE
3 x
HOLD
18
– Function mode « REL ZERO »
6.6 Temporary reset to zero (relative measurement) on a surface with given references
Note:
Any previous initial (zero) setting of display made in mode « ABSOLUTE » remains
unchanged
Function Key Display
CLINOBEVEL 2 is ready to
measure with display set to
zero based on the centre of
gravity as per chapter 6.2
Place the inclinometer
on the given
reference surface
Activate
« Temporary
zero-setting »
Capture the inclination value
of the temporary reference
surface against initial (zero)
setting stored