EasyManua.ls Logo

Tesmec PT2450 - Command “Connected Machine”

Tesmec PT2450
154 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
HYDRAULIC PULLER TENSIONER PT2450
Manual: MI-PT2450-050-00-GB Date: 28.07.2018 Author: AT Page: 73 of 89
6.1.2 COMMAND “CONNECTED MACHINE”
In the following pages there are the possible commands that can be made with the machines in electronic
connection:
When using connected machines, the following controls effect on all machines when operated from the
MASTER machine:
Speed control (with relative Joystick);
Pull-adjusting control (with relative potentiometer);
Rope-clamp selector (with relative switch);
Active / de-active electronic synchronize (with relative switch) - (see Cap.6.1.3).
While the following commands / settings must be performed on each individual SLAVE machine:
Reel-winder working pressure (with relative potentiometer);
Reset of meter counter (with relative button on control panel - see cap. 5.5.1);
Positioning the rear and back plug (with relative button on control panel - see cap. 5.5.2.2.);
Joystick
speed control
Rope
clamp
Pull force
value
synchronize
switch
Reel winder pressure
control