5.4 MACHINE USE – ELECTRONIC CONNECTION WITH INDIPENDENT BULL-WHEEL
The electronic connection allow to connect electronically circuit 1 and circuit 2 and the operator have the
possibility to control both circuit with the one series of controls.
It’s possible active the electronic connection between the switch [1<2] on the radio remote control. In this
configuration, it’s possible active the electronic synchronize: this system allows you to automatically align
the speeds of both circuits so that you can have the conductor or ropes at the same height during the
stringing operations.
To active the electronic connection and use the machine in this configuration, follow the step below:
1- To use the electronic connection, it’s necessary to have the bull-wheel circuit in independent configuration:
2- To active the electronic connection, switch ON the switch on the radio remote control.
On the main work screen, the corresponding
symbol will be displayed if it activates the
electronic connection and electronic
synchronization.
NOTE: Electronic synchronization can only be
activated when the electronic connection is
active.
Electronic
Connection
Synchronize