Programming the Control Panel Premier 48, 88, 168 & 640 Installation Manual
80 INS176
No Type Event Reporting Group Contact ID SIA ID
30 Exit Started Alarm Not Reported - - Keypad No
Restore Not Reported - - -
31 Exit Error (Arming Failed) Alarm Open/Close 457 EE 00
Restore Not Reported - - -
32 Entry Started Alarm Not Reported - - -
Restore Not Reported - - -
33 Area Arm Suite Alarm Open/Close - - Suite No 1 - 8
Restore Open/Close - - -
34 Armed with Line Fault Alarm Not Reported - - User No
Restore Not Reported - - -
35 Open/Close (Full Arm) Alarm Open/Close 401 OP User No
Restore Open/Close 401 CL User No
36 Open/Close (Part Arm) Alarm Open/Close 401 OP User No
Restore Open/Close 401 CL User No
37 Auto Open/Close Alarm Open/Close 403 OA 00
Restore Open/Close 403 CA 00
38 Auto Arm Deferred Alarm Open/Close 405 CE User No
Restore Open/Close - - -
39 Open After Alarm (Alarm Abort) Alarm Open/Close 406 OR 00
Restore Not Reported - - -
40 Remote Open/Close Alarm Open/Close 407 OP 00
Restore Open/Close 407 CL 00
41 Quick Arm Alarm Not Reported - - -
Restore Open/Close 408 CL Keypad No *
42 Recent Closing Alarm Open/Close 459 CR 00
Restore Not Reported - - -
43 Reset After Alarm Alarm Restore - - Reset ID ****
Restore Not Reported - - -
44 Auxiliary 12V Fuse Fail Alarm Maintenance 300 YP Device ID **
Restore Restore 300 YQ Device ID **
45 AC Fail Alarm Maintenance 301 AT 00
Restore Restore 301 AR 00
46 Low Battery Alarm Maintenance 302 YT 00
Restore Restore 302 YR 00
47 System Power Up Alarm Maintenance 305 RR 00
Restore Not Reported - - -
48 Bell Fuse Failure Alarm Maintenance 321 YA 00
Restore Restore 321 YH 00
49 ATS Path Fault Alarm Maintenance 351 LT Line Fault ID ***
Restore Restore 351 LR Line Fault ID ***
50 Fail to Communicate Alarm Maintenance 354 YC 00
Restore Not Reported - - -
51 Download Start Alarm Maintenance 411 RB 00
Restore Not Reported - - -
52 Download End Alarm Maintenance 412 RS -
Restore Not Reported - - -
53 Log Capacity Alert (80%) Alarm Maintenance 623 JL 00
Restore Not Reported - - -
54 Date Changed Alarm Maintenance 625 JD User No
Restore Not Reported - - -
55 Time Changed Alarm Maintenance 625 JT User No
Restore Not Reported - - -
56 Installer Programming Start Alarm Maintenance 627 LB User No
Restore Not Reported - - -