No Type Event Reporting Group Contact ID SIA ID
84 Log Cleared Alarm Maintenance - - -
Restore Not Reported 401 CL 000
85 iD Loop Shorted Alarm Tamper 145 TA 000
Restore Restore 145 TR -
86 Communication Port Alarm Maintenance - - 000
Restore Restore - - 000
87 TAG System Exit (Batt. OK) Alarm Not Reported - - Zone No
Restore Not Reported - - Zone No
88 TAG System Exit (Batt. LOW) Alarm Not Reported - - -
Restore Not Reported - - -
89 TAG System Entry (Batt. OK) Alarm Not Reported - - -
Restore Not Reported - - -
90 TAG System Entry (Batt. LOW) Alarm Not Reported - - -
Restore Not Reported - - -
91 Microphone Activated Alarm Not Reported - - -
Restore Not Reported - - -
92 AV Cleared Doen Alarm Not Reported - - -
Restore Not Reported - - -
93 Monitored Alarm Alarm Alarm 220 BA Zone No
Restore Restore 220 BH Zone No
94 Expander Low Voltage Alarm Maintenance 143 ET Device No
Restore Restore 143 ER Device No
95 Supervision Fault Alarm Maintenance 355 UT Zone No
Restore Restore 355 UJ Zone No
96 PA From Remote FOB Alarm Priority Alarm 121 121 Zone No
Restore Restore HA HH Zone No
97 RF Device Low Battery Alarm Maintenance 384 XT Zone/User No
Restore Restore 384 XR Zone/User No
98 Site Data Changed Alarm Maintenance - - -
Restore Restore - - -
99 Radio Jamming Alarm Maintenance 344 XQ 000
Restore Restore 344 - 000
100 Test Call Passed Alarm Not Reported - - -
Restore Not Reported - - -
101 Test Call Failed Alarm Not Reported - - -
Restore Not Reported - - -
102 Zone Fault Alarm Maintenance 380 UT Zone No
Restore Restore 380 UJ Zone No
103 Zone Masked Alarm Alarm 380 UT Zone No
Restore Restore 380 UJ Zone No
104 Faults Overridden Alarm Maintenance - - 000
Restore Not Reported - - 000
105 PSU AC Fail Alarm Maintenance 301 AT Device No
Restore Restore 301 AR Device No
106 PSU Low Battery Fail Alarm Maintenance 302 YT Device No
Restore Restore 302 YR Device No
107 PSU Low Output Fail Alarm Maintenance 300 YP Device No
Restore Restore 300 YQ Device No
108 PSU Tamper Alarm Tamper 333 TA Device No
Restore Restore 333 TR Device No