Premier 8XP-W & 32XP-W Installation Manual
20
1. Select engineers mode by entering the engineer code followed by / then .
2. Enter  to select the Assign Radio Device menu, if an error tone is generated then the
receiver is not installed or configured correctly.
3. Enter the two digit zone number that you want to assign the detector to e.g., .
4. Remove the cover of the detector so that it generates a tamper condition. If the cover was
already open press the tamper switch then release it. The panel will generate an acceptance
tone and the detector is now assigned to the selected zone.
5. Program the zone type and attributes as required. Note: The Zone Wiring must be
programmed asDouble EOL, if a tamper response is required from the detector.
6. Repeat steps 2 - 5 for other detector
Removing Detectors
If a detector is no longer required it must be unassigned from the system. To remove a detector from
a zone, proceed as follows:
1. Select engineers mode by entering the engineer code followed by / then .
2. Enter  to select the All Zone Options menu.
3. Enter the two digit zone number that you want to remove the detector from e.g., .
4. Enter  to program the zone type as Null. The panel will generate an acceptance tone
and the detector is no longer assigned to the selected zone.
 
  
  
  
