Premier 8XP-W & 32XP-W Installation Manual
19
Premier 412/816 V10.5 V11.07 & Premier 832 V3.50.-.V4.07
Follow these instructions to learn devices to the system, once completed follow the relevant section
of the control panel manual to programme zones and user attributes.
Option Switch Settings
Premier 412/816 V10.95 Premier 832 V3.95 and lower of firmware switch 1,2 & 3 should be ON.
Premier 412/816 V10.96 V11.07 Premier 832 V3.96 V4.07 of firmware switch 2 & 3 should be ON
Expander Settings
The expander should be set to address 1.
Premier SmartKey Status LED Indications
With these versions of control panel firmware it is not possible to get status indications from the
control panel. LED Status indication should be turned off using either RICOCHET Monitor or the
Engineers Keypad.
All devices first need to learned to the expander, this can be done either via the learn LED’s onboard
the expander see page 23, the Engineers keypad see page 24 or RICOCHET™ Monitor PC
software. Once learned the Assign Radio Devices menu may be used to allocate devices to the
control panel as follows:-
Detectors are assigned to zones as follows:
 
  
  
  

Ent er Z one
Number

  
 
Accept ance Tone
from Panel
Remove the cover of the
detect or so that it generat es a
tamper condit ion. I f the cover
was already open press t he
tamper switch t hen release it .
Ent er Engineers code
Then press then
/
