Premier 8XP-W & 32XP-W Installation Manual
16
Removing Detectors
If a detector is no longer required it must be unassigned from the system. To remove a detector from
a zone, proceed as follows:
1. Select engineers mode by entering the engineer code followed by / then .
2. Enter  to select the All Zone Options menu.
3. Enter the two digit zone number that you want to remove the detector from e.g., .
4. Enter  to program the zone type as Null. The panel will generate an acceptance tone
and the detector is no longer assigned to the selected zone.
Learning Premier SmartKey
All Premier SmartKey must be assigned to one of the available users on the system. The users
available will vary depending on the control panel:
Control Panel Available Users
Premier 412 Users 1 to 31
Premier 816 Users 1 to 31
Premier 832 Users 1 to 63
 
  
  
  

Ent er Z one
Number

  

Enter Engineers code
Then press then
/

Accept ance Tone
from Panel
