Premier 8XP-W & 32XP-W Installation Manual
33
Impaq Contact-W
The Impaq Contact-W has 3 additional inputs labelled MAG 1 COM MAG 2, these inputs can be
used for any N/C device. If the Reed switch is disabled the device can be used as a transmitter for
any device wired into one of the two inputs.
The two additional inputs are NOT independently programmable of the reed switch, when mapped
to a panel zone if either the reed switch or any of the inputs are triggered the zone which the device
is mapped too will go active.
Switch 3 on the expander controls how MAG 2/COM reports to the control panel. By default the
switch is on and anything connected to MAG 2/COM will report as a tamper. When switch 3 is OFF
MAG 2/COM will report as alarm.
In the case of the Impaq Contact –W being used to trigger 24 hour circuits, or where the zone is
required to chime, the device attributes should be changed to Always Awake as detailed on page
34.
The two additional inputs may also be used to transmit N/C signals from any other locally powered
or self powered device, depending on the type of device used you should choose the device
attributes to suit.
Walktest Mode
Walktest Mode can be initiated from the Control Panel, Engineers Keypad, RICOCHET™ Monitor or
directly on the expander.
When in Walktest mode LED’s are enabled and the response time for devices between activations is
reduced to 10 seconds. Walktest will last for 1 hour.
Control Panel
Please refer to the Control Panel installation instructions to enter Walktest mode. The countdown
timer does NOT appear on the panel’s keypad.
Expander
Option switch 4 toggles Walktest mode on and off. To enable Walktest mode from the expander
switch Option switch 4 to the ON position. To leave Walktest mode turn option switch 4 OFF. The
countdown timer will be visible on the engineer’s keypad or RICOCHET™ Monitor.
Engineers Keypad
See page 33. The countdown timer will appear.
RICOCHET™ Monitor
Press the button. The countdown timer will appear.