1: Engineers Keypad Connection
An engineer’s keypad (Premier LCD keypad and interface lead) can be temporarily plugged onto
this connector to allow system programming and testing. (Functions dependent on Panel firmware
version) Set the keypad address switches to all on.
2: Network Connection
The + and – terminals provide power whilst the T and R terminals are transmit and receive data.
3: For Future Use
4: Comm. Port Connection
Serial communications port for connecting the 8 XP-W & 32XP-W to a PC via PC Com/USB Com