Premier 8XP-W & 32XP-W Installation Manual
13
Premier 24 V7.00-V8.23, 48/88/168 V7.00 V8.14, 640 V7.00-V8.15
Option Switch Settings
For V7.00-V8.11 of firmware switch 1 2 & 3 should be ON for all panels.
For Versions prior to V7.40 on the Premier 24, Learned devices should be mapped to zones 9-24 only, it
is not possible to map to Zones 1-8. This means the maximum number of devices excluding SmartKey™
is 15 with this version of firmware.
For V 8.11 > of firmware only switches 2 & 3 should be ON.
Expander Settings
The expander can be set to any valid address.
Premier SmartKey Status LED Indications
To utilise the full functionality of the Premier SmartKey the expander outputs should be
programmed as follows for expander 1 on the control panel.
1.Area .... Exit
2.Area .... Armed
3.Area .... Part Arming (Part Arm 1 on the Premier 24)
4.Area .... Part Armed
5.Area .... Alarm
6.Area .... Panic Alarm
7.Area .... Walktest
The other outputs on the expander must be set to Not Used.
All devices first need to learned to the expander, this can be done either via the learn LED’s onboard
the expander see page 23, the Engineers keypad see page 24 or RICOCHET Monitor PC
software.
Once learned the Configure Radio menu may be used to assign the devices to the control panel.
It is possible to learn the devices to both the receiver and the control panel at the same time,
however great care should be taken to ensure devices are learned to the correct slots in both
instances.
For example to learn a device to slot 11 scroll to device 11 on the control panel keypad and press
YES. Then learn device 11 via the LED’s, Engineers Keypad or PC Software.
Once learned a tamper signal will be transmitted and the device will be allocated to slot 11 on the
control panel. Press NO on the Control Panel keypad to map the device to a zone/user. Follow
instructions in the Control Panel manual to assign the zone types, attributes etc.