EasyManua.ls Logo

Texecom Premier 8XP-W - Premier SmartKey Features; LED Indications; PA Activation and Auxiliary Functions; Alarm Status and Arm Fail Indications

Texecom Premier 8XP-W
44 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Premier 8XP-W & 32XP-W Installation Manual
35
Premier SmartKey
LED Indications
Premier SmartKey™ Status LED
The Status LED has four colours. This LED cannot be disabled.
1. Pink = Power Up or Down
2. Green = Successful communication with the system
3. Flashing Blue = communication with system.
4. Red = Out of Range
5. Turquoise = Function Mode
POWER
FUNC TION 1/PC Control 1
FUNC TION 3/PC Control 3
FUNC TION 2/PC Control 2
Function S tatus L E Ds
Premier SmartKey s ta tus L E D
FUNCTION 3
FUNCTION 2
FUNCTION 1
on Premier 412 816 & 832 Function 1 is the Arm Button and Function 2 is the Disarm button.
PA Activation
By default PA activation is enabled on the Premier SmartKey, however the control panel should
be programmed to enable Radio PA. Please refer to your Control Panel manual for details.
Enable/Disable Alarm Status LED’s
The Alarm Status LED’s can be enabled or disabled either from the Engineers Keypad see page 27,
or RICOCHET™ Monitor.
Alarm Status LED’s are not available on the Legacy Premier 412, 816 & 832. For legacy Premier
24/48/88/168 & 640 please see page 13 to programme the output functions required to enable
the LED indications.