1.
Overview
4-4
4. TSC Functions
TSC
1-3
Timing chart (Common to position move)
The timing chart of each signal during general position movement for mode 0 to 3 is described
below. For details of the chart for each mode, see the respective timing chart.
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
End position "PO□"
Instruction position
number input
"PI□"
Start input "STRT"
Moving "MOVE"
Positioning
completed output
"INPS"
10 ms or more
10 ms or more
10 ms or more
10 ms or more
Note 1
Note 2 Note 2 Note 2
Pos Range
Note 1: If input is made before "INPS" turns ON,
multi step transmission operation is activated after "INPS" turns ON
Note 2: The delay time is up to several milliseconds
Note 2
Pos Range Pos Range