1.
Overview
4-4
4. TSC Functions
TSC
1-3
Timing chart (Common to position move)
The timing chart of each signal during general position movement for mode 0 to 3 is described
below. For details of the chart for each mode, see the respective timing chart.
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
End position "PO"
Instruction position
number input
"PI"
Start input "STRT"
Moving "MOVE"
Positioning
completed output
"INPS"
10 ms or more
10 ms or more
10 ms or more
10 ms or more
Note 1
Note 2 Note 2 Note 2
Pos Range
Note 1: If input is made before "INPS" turns ON,
multi step transmission operation is activated after "INPS" turns ON
Note 2: The delay time is up to several milliseconds
Note 2
Pos Range Pos Range