13.
General precautions
5-18
5. Operations and
adjustment
TSC
13-1
General precautions
(1) To receive the next STRT signal or ST 0 to 6 signals after the completion of movement,
INPS
(pin.30) and LS (pin.19 to 21) signals ON, the intervals of more than 10 ms are necessary.
(2) In the function modes 0 and 1, the MOVE output (pin.25) turns ON until the movement comple-
tion program. Especially, when the MOVE output (pin.25) turns OFF without the INPS output
(pin.30) ON for the pressing operation, please determine that pressing failed (missed).