6. Troubleshooting
2.
Alarm code
6-4
TSC
2-1
Alarm code
Upon alarm generation, the ALM output (pin.34) is turned OFF. (ON is the normal status)
In the event of any alarm, the binary alarm code is output to (AC 0 to 5) as the STEP No. is output
in binary to PO 0-8, whose operation has been completed in Function modes 0 through 3. (See
"2-3 How to obtain STEP No. whose operation has been completed (
P.4-5)".)
Assuming the (AC) is equivalent to each binary number digit, convert them into decimal numbers
to obtain an alarm code.
Obtain the decimal numbers of the (AC) being ON from the table above, and add all the numbers
up to determine the current alarm code.
Example) When (AO 5) (=32), (AO 4) (=16), (AO 1) (=2), and (AO 0) (=1) are ON
32 + 16 + 2 + 1 = 51, so alarm code = 51.
(AC) 0 1 2 3 4 5
Binary number digits
2
0
2
1
2
2
2
3
2
4
2
5
Decimal number 1 2 4 8 16 32