EasyManua.ls Logo

THK TSC Series - Timing Chart

Default Icon
100 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4-13
5.
Function mode 5
4. TSC Functions
TSC
5-4
Timing chart
A start signal (ST 0 to ST 2) is available for each STEP No., and turning ON the corresponding
start signal will operate the actuator according to the program set to each STEP No.
The position detection output (LS 0 to LS 2) turns ON according to the "Position (mm)" set to
each STEP No.
ON range depends on the "Pos range (mm)".
The zero return input HOME and ST 0 to ST 2 detect the rising edge from signal OFF to ON.
TSC power supply
Servo on input "SV-ON"
Zero return input "HOME"
Cylinder type START input "ST0 to ST2"
Operation preparations completed output "SVRDY"
Zero return completed output "HEND"
Cylinder type position detection output "LS0"
Cylinder type position detection output "LS1"
Cylinder type position detection output "LS2"
Target position
(Pos Range, target position: Position table setting values)
Target position Target position
Pos Range
Pos Range
Pos Range
During servo on During zero return During the operation
T1, T2: 10 ms or more

Table of Contents