REVUE THOMMEN AG
CH-4437 Waldenburg
AD20 Standby Altimeter
Page 72 of 72
07-Sep-2009 Document No: AD-INSOP-800 Revision: 1.6
6.3 APPENDIX III: Altimeter Calibration Table
Altitude
[feet]
Tolerance acc. to ETSO/TSO-C10b
± [feet]
(Baro setting 1’013 hPa) @ 25 °C
(77 °F)
@ - 30 / + 71°C 1)
(-22 / +160 °F)
-1’000
0
500
1'000
1'500
2‘000
3‘000
4‘000
6‘000
8‘000
10'000
12'000
14‘000
16'000
18‘000
20'000
22‘000
25'000
30'000
35'000
40'000
45‘000
50’000
55'000
20
20
20
20
25
30
30
35
40
60
80
90
100
110
120
130
140
155
180
205
230
255
280
(305)
--
40
--
--
--
--
--
--
60
--
--
90
--
--
120
--
--
155
--
205
--
--
280
--
Table 6-3 Altimeter Calibration Table
1) allowable change from room temperature scale error test indication