Appendix B – Configuring HECO Requirements – Zero Export
EI Residential Solar Solution US Installation Manual | www.tigoenergy.com | Help Center 72
Appendix B Configuring HECO Requirements
The Hawaiian Electric Company's (HECO) tariff Rule No. 14 Section H concerns the
interconnection of distributed generating facilities operating in parallel with the company's
electric system.
To configure the inverter for HECO requirements, you must set voltage levels and disable
sending energy to the grid with the
Zero Export
setting.
To set voltage levels:
1. Open the Tigo Energy Intelligence mobile app.
2. Select
Settings > Edit System > Select Equipment > Inverter > View Details > Connect
> Inverter Settings > Grid Code > Advanced Options > HECO
.
3. Select
Advanced Options > Voltage Level
and set appropriate levels.
To configure
Zero Export
settings:
1. Open the Tigo Energy Intelligence mobile app.
2. Select
Settings > Edit System > Select Equipment > Inverter > View Details > Connect
> Inverter Settings > Grid Code > Advanced Options > AC Meter
.
3. Toggle off the
Export Power Allowed
setting.