44
9.3.2. Cutoff frequency settings
[ OUT 1 ] XOVER - HF
FREQ 1.00kH
z
[ OUT 1 ] XOVER - L F
FREQ 1.00kH
z
(Low frequency)
(High frequency)
PARAMETER
PUSH-ENTER
CHANGE
PARAMETER
PUSH-ENTER
CHANGE
Rotate the Setting knob to set the cutoff frequency.
Parameter setting range: 20 Hz 20 kHz in 1/24 octave steps
Pressing an Output channel selector key permits the crossover
filter to be set for that channel. The [OUT 1] indication changes to
the selected channel number indication.
9.3.3. Q settings
[ OUT 1 ] XOVER - HF
Q 0.50
0
[ OUT 1 ] XOVER - L F
Q 0.50
0
(Low frequency)
(High frequency)
PARAMETER
PUSH-ENTER
CHANGE
PARAMETER
PUSH-ENTER
CHANGE
The Q setting can be performed only when the type of slope is
VQ.
Rotate the Setting knob to set the Q.
Parameter setting range: 0.500 2.563 (51 points)
Pressing an Output channel selector key permits the crossover
filter to be set for that channel. The [OUT 1] indication changes to
the selected channel number indication.
9.3.4. Q2 settings
[ OUT 1 ] XOVER - HF
Q2 0.50
0
[ OUT 1 ] XOVER - L F
Q2 0.50
0
(Low frequency)
(High frequency)
PARAMETER
PUSH-ENTER
CHANGE
PARAMETER
PUSH-ENTER
CHANGE
The Q2 setting can be performed only when the type of slope is
24VQ.
Rotate the Setting knob to set the Q2.
Parameter setting range: 0.500 2.563 (51 points)
Pressing an Output channel selector key permits the crossover
filter to be set for that channel. The [OUT 1] indication changes to
the selected channel number indication.
9.3.5. Crossover gain settings
[ OUT 1 ] XOVER - HF
GAIN +0.0d
B
[ OUT 1 ] XOVER - L F
GAIN +0.0d
B
(Low frequency)
(High frequency)
PARAMETER
PUSH-ENTER
CHANGE
PARAMETER
PUSH-ENTER
CHANGE
Rotate the Setting knob to set the crossover gain.
Parameter setting range: 15 to +15 dB in 0.1 dB steps
Pressing an Output channel selector key permits the crossover
filter to be set for that channel. The [OUT 1] indication changes to
the selected channel number indication.
9.3.6. Crossover filter polarity settings
(Low frequency)
(High frequency)
PARAMETER
PUSH-ENTER
CHANGE
PARAMETER
PUSH-ENTER
CHANGE
[ OUT 1 ] XOVER - HF
POL NORMA
L
[ OUT 1 ] XOVER - L F
POL NORMA
L
Rotate the Setting knob to set the crossover filter polarity.
Parameter setting range: NORMAL and INVERSE
Pressing an Output channel selector key permits the crossover
filter to be set for that channel. The [OUT 1] indication changes to
the selected channel number indication.

Table of Contents