D4008 – EN EZ 2810 Operators Manual 33
SETTING
[display]
D.A.N
NO.
OPTIONS [displayed]
BOLD=DEFAULT
DESCRIPTION
PRE-ALARM
4002 100
Enter a value to activate an early warning that indicator is reaching the
preset.
ALARM OUTPUT
4003 OFF, PRESET, TR Select preset or TR to control relay, horn & lamp.
BUZZER
4004 OFF, ON, 1-10
ALARM BUZZER -allows user to turn off alarm horn when
loading/unloading
RELAY
4005 OFF, PRESET, SETPNT Selects the behavior of the +12VDC alarm output
PRESET DELAY
4006 0 thru 9 Set time to automatically advance/print entered preset
OUTPUT
4101 OVER/UNDER Select when the +12VDC Alarm Output becomes active.
GROSS SET
POINT CHNG
4102 500 Set required weight change to turn off +12VDC Alarm Output.
GROSS SET
POINT DELAY
4103 0 thru 9 Set time delay before the +12VDC Alarm Output can Turn On/Off.
GROSS SET
POINT
4104 5000
Set a gross weight in long form that will activate +12VDC Alarm
Output on Power cord.
SET POINT
COUNT
4105 0 thru 9
Counts how many times set point is activated.
SET POINT
WEIGHT
SOURCE
4106 SERIAL/NORMAL Sets weight source for use with set point feature.
TOLERANCE
METHOD
4201 WEIGHT, PERCENT
Select weight or percentage method for preset tolerance
TOLERANCE
4202 0 thru 9 Select tolerance weight percentage to accept preset.
TOLERANCE
OVERLOCK
4203 OFF/ON Prevents auto-advancing if preset exceeds tolerance
TIMER,
COUNTER
4301 TIMER, COUNTER Select time or mixer revolutions to decrement mix timer/counter.
DRIVE RATIO
4302 0001.00
Enter the number of input pulses that equal 1 mixer revolution.
REVCTR needs to
be enabled in the setup options. D.A.N. 4301 set to
COUNTER.
MENU 5 - COM PORT SETUP
REMOTE
DISPLAY PORT
5001
OFF, COM1, COM2,
COM3
Sets serial remote display output
RADIO PORT
5002
OFF, COM1, COM2,
COM3
Sets internal radio port
EXTERNAL
RADIO PORT
5003
OFF, COM1, COM2,
COM3
Sets external radio port
PRINTER PORT
5005
OFF, COM1, COM2,
COM3
Sets printer port
SCOREBOARD
PORT
5006
OFF, COM1, COM2,
COM3