5.1. Opening auto section control
58
chosen, some overlap of application is likely near boundaries. The
default (50) is a compromise.
l Boundary limit: Sets which type of boundary limit will turn off
spraying when using auto section control.
Field Boundary and Headland are defined using the Field menu
on the Operation screen. Refer to the Guidance and Auto Steering
Operator Manual for more information on these.
Safety Zone reduces width of spreading by half a swath width
from the boundary to prevent over application.
l ASC on/off: Turn auto section control on/off.