Chapter 3 Athene Setup
31
10.
Select Factory / Loadcell Interfaces / Loadcell Calibration.
11. When prompted ‘Is spreader empty?’ select NO and enter the actual
weight in the spreader.
3.5.1. Load cell calibration
Load cells may drift out of calibration after an initial period of 'bedding
in' on a new machine.
To recalibrate, repeat the procedure detailed above from step 6.