EasyManua.ls Logo

Toro Groundsmaster 4010-D - Sound Power Level; Sound Pressure Level-Model 30607; Sound Pressure Level-Model 30609; Vibration Level-Model 30607

Toro Groundsmaster 4010-D
64 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SoundPowerLevel
Thisunithasaguaranteedsoundpowerlevelof104dBA,
whichincludesanUncertaintyValue(K)of1dBA.
Soundpowerlevelwasdeterminedaccordingtothe
proceduresoutlinedinISO11094.
SoundPressureLevel-Model
30607
Thisunithasasoundpressurelevelattheoperator’searof89
dBA,whichincludesanUncertaintyValue(K)of1dBA.
Soundpressurelevelwasdeterminedaccordingtothe
proceduresoutlinedinEN836.
SoundPressureLevel-Model
30609
Thisunithasasoundpressurelevelattheoperator’searof90
dBA,whichincludesanUncertaintyValue(K)of1dBA.
Soundpressurelevelwasdeterminedaccordingtothe
proceduresoutlinedinEN836.
VibrationLevel—Model30607
Hand-Arm
Measuredvibrationlevelforrighthand=0.58m/s
2
Measuredvibrationlevelforlefthand=0.63m/s
2
UncertaintyValue(K)=0.32m/s
2
Measuredvaluesweredeterminedaccordingtotheprocedures
outlinedinEN836.
WholeBody
Measuredvibrationlevel=0.26m/s
2
UncertaintyValue(K)=0.13m/s
2
Measuredvaluesweredeterminedaccordingtotheprocedures
outlinedinEN836.
VibrationLevel—Model30609
Hand-Arm
Measuredvibrationlevelforrighthand=1.1m/s
2
Measuredvibrationlevelforlefthand=1m/s
2
UncertaintyValue(K)=0.5m/s
2
Measuredvaluesweredeterminedaccordingtotheprocedures
outlinedinEN836.
WholeBody
Measuredvibrationlevel=0.29m/s
2
UncertaintyValue(K)=0.15m/s
2
Measuredvaluesweredeterminedaccordingtotheprocedures
outlinedinEN836.
EngineEmissionCertication
TheengineinthismachineisEPATier4Finalandstage3b
compliant.
7

Table of Contents

Other manuals for Toro Groundsmaster 4010-D

Related product manuals