Spray-PumpSwitch
Thespray-pumpswitchislocatedonthecenter
consoletotherightoftheseat(Figure13).Togglethis
switchforwardtorunthespraypumporrearwardto
stopthepump.Whentheswitchisturnedon,alight
ontheswitchilluminates.
Important:Engagethespray-pumpswitchonly
whentheengineisatLOWIDLEtoavoiddamaging
thepumpdrive.
Boom-SectionLiftSwitches
Theboom-sectionliftswitchesarelocatedonthe
centerconsoletotherightoftheseatandusedto
raiseorlowertheleftandrightboomsections(Figure
13).
MasterSectionSwitch
Themastersectionswitchislocatedonthecenter
consoleofthemachine.Thisswitchallowsyouto
startorstopthesprayoperation.Presstheswitchto
enableordisablethespraysystem(Figure13).
Left,Center,andRightSectionSwitches
The3sectionswitchesarelocatedonthecenter
consoleinthefrontofthearmrest(Figure13).Toggle
eachswitchforwardtoturnthecorrespondingsection
onandrearwardtoturneachoff.Whentheswitchis
intheONposition,aniconappearsatthetopofthe
InfoCenter.
Note:Theseswitchesaffectthespraysystemonly
whenthemastersectionswitchisintheONposition.
AgitationSwitch
Theagitationswitchislocatedonthecenterconsole
totherightoftheseat(Figure13).T ogglethisswitch
forwardtoturnontheagitationinthetankorrearward
tostoptheagitation.Whentheswitchisturnedon,a
lightontheswitchilluminates.Tooperatetheagitation
function,youmustrunthesprayersystempumpand
youmustruntheengineabovelowidle.
Agitation-BypassValve
Theagitation-bypassvalveredirectstheowofuid
tothesprayer-systempumpwhenyouturnoffthe
agitationfunction(Figure14).Theagitation-bypass
valveislocatedabovetheagitationvalve.Youcan
adjustthebypassvalvetoensurethatthepressure
remainsconstantwhencyclingagitationonoroff;refer
toCalibratingtheAgitation-BypassValve(page29).
g194246
Figure14
1.Actuator(agitationvalve)
3.Flowmeter
2.Agitation-bypass-valve
handle
FlowMeter
Theowmetermeasurestheowrateoftheuidfor
usebytheInfoCentersystemandwhensprayingin
theapplicationratemode(Figure14).
Agitation-ThrottleValve
Theagitation-throttlevalveisamanually-operatedball
valvethatcontrolsowtotheagitationnozzlesinthe
maintank.Thisvalveallowsthesprayeroperatorto
controlthesprayer-systempressureattheagitation
nozzlesofthemaintankwhenlargerapplicationrates
arerequired.Theagitation-throttlevalveislocated
abovethepump(Figure15).
g032528
Figure15
1.Agitation-throttle-valvehandle
19