SectionBypassValves
Thesectionbypassvalvesareusedtoadjustthe
sprayersystempressuretothesectionvalvesto
ensurethatthesprayerpressuretothespraysection
remainsconstantnomatterhowmanyspraysections
areon(Figure16).
Note:Usethebypassvalveswhensprayinginthe
manualmode(openloop)only.
g190774
Figure16
1.Knob(section-bypass
valves)
2.Section-bypassshutoff
valve
Section-BypassShutoffValve
Usethesection-bypassshutoffvalvetocontroluid
owfromthesectionbypassvalvestothetankwhen
sprayinginthemanualmode(openloop);referto
Figure16.
Note:Closethesection-bypassshutoffvalvewhen
sprayingintheapplicationratemode(closedloop).
Anti-SiphonFillReceptacle
Atthefrontofthetankcoverisahosereceptacle
withathreadedtting,a90-degreebarbedtting,
andashorthose,whichyoucandirecttowardthe
tankopening.Thisreceptacleallowsyoutoconnect
awaterhosetoitandllthetankwithwaterwithout
contaminatingthehosewiththechemicalsinthetank.
Important:Donotlengthenthehosetoallow
contactwiththetankuids.Thedistancefrom
theendofthehosetotheuppermostwaterlevel
shouldbewithinlocalregulatorylimits.
g013787
Figure17
1.Anti-siphonllreceptacle
2.Tankcover
TankCover
Thetankcoverislocatedatthecenter,topofthe
tank.Toopenthecover,shutofftheengine,turnthe
fronthalfofthecovertotheleft,andswingitopen.
Youcanremovethestrainerinsideforcleaning.T o
sealthetank,closethecoverandrotatethefronthalf
towardtheright.